- The next step involves using a thin layer of Ecoflex 0030 to bond the top and bottom halves of the sensor. If the layer is too thick, it will plug the channels. To ensure a thin, uniform layer a spincoater is used.
- The spincoater should be set to 2000 RPM for 60 Seconds.
- As done in the previous step, mix a small amount of EcoFlex 0030 and degas it.
- Refer to the Bill of Materials section for vendor information for EcoFlex.
|
|